Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22.398
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 380, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745214

RESUMEN

BACKGROUND: Enlargement of the bone tunnel has become an unavoidable early complication after anterior cruciate ligament (ACL) reconstruction, whether it is a single or double-bundle ACL reconstruction. Preservation of the ACL stump in ACL reconstruction reduces enlargement of the bone tunnel. The purpose of this study was to investigate the question of whether single-bundle ACL reconstruction using the ACL femoral side retained stump technique reduces enlargement of the femoral tunnel. METHODS: Forty patients who underwent single-bundle reconstruction of the ACL were included in this study. The patients were categorized into a Remnant preservation group (Group R) and the Non-remnant preservation group (Group N). In the Remnant preservation group, a high-flexion femoral side retained stump technique was used intraoperatively for the establishment of the femoral side bone tunnel, and in the Non-remnant preservation group, the conventional femoral positioning method was used (we used a femoral positioning drill for localization and drilling of the femoral bone tunnel), and MRI of the operated knee joints was performed at 6 months postoperatively. We measured the internal diameter of the femoral bone tunnel at 5 mm from the intra-articular outlet of the femoral bone tunnel on an MRI scan image perpendicular to the femoral bone tunnel. The size of the tunnel was compared between the intraoperative drilling of the bone tunnel and the size of the bone tunnel at 6 months postoperatively. Postoperative clinical assessment was Lysholm score. RESULTS: After a 6-month follow-up of 40 patients, the diameter of the femoral tunnel at a distance of 5 mm from the inner opening of the femoral tunnel was 10.96 ± 0.67 mm and 10.11 ± 0.62 mm in patients of group N and group R, respectively, and the difference was statistically significant (P < 0.05).The diameter of the femoral tunnel at 6 months postoperatively in group N and group R compared to the intraoperative bone tunnel increased by 2.58 ± 0.24 mm and 1.94 ± 0.31 mm, and the difference was statistically significant (P < 0.05).The femoral tunnel enlargement rates of group N and group R were 30.94 ± 3.00% and 24.02 ± 5.10%, respectively, and the differences were significant (P < 0.05). CONCLUSION: ACL femoral side retained stump technique does not sacrifice the ideal location of the femoral tunnel and is able to preserve the possible benefits of the ACL stump: reduced femoral tunnel enlargement.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Fémur , Humanos , Reconstrucción del Ligamento Cruzado Anterior/métodos , Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Fémur/cirugía , Fémur/diagnóstico por imagen , Adulto , Femenino , Masculino , Adulto Joven , Ligamento Cruzado Anterior/cirugía , Ligamento Cruzado Anterior/diagnóstico por imagen , Adolescente , Lesiones del Ligamento Cruzado Anterior/cirugía , Imagen por Resonancia Magnética , Resultado del Tratamiento , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Persona de Mediana Edad
2.
Int J Med Robot ; 20(3): e2635, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38733580

RESUMEN

BACKGROUND: Rotational alignment in total knee arthroplasty (TKA) is a crucial technical point that needs attention. We conducted a retrospective study to investigate whether a new robot-assisted TKA (RA-TKA) could improve the accuracy of rotational alignment and whether rotational alignment affects postoperative pain and functional evaluation of the knee. METHODS: A total of 136 consecutive patients who underwent TKA were included in this study. Half of the patients underwent RA-TKA and the other half underwent conventional TKA (CON-TKA) by the same group of surgeons. Collect the relevant parameters. RESULTS: The postoperative femoral rotation angle (FRA) was -0.72 ± 2.59° in the robot-assisted group and 1.13 ± 2.73° in the conventional group, and were statistically significantly different (p < 0.001). CONCLUSION: This study provides preliminary evidence that the RA-TKA provides more precise control of FRA than CON-TKA, and verifies that tibial rotation angle and combined rotation angle affect postoperative knee pain and functional evaluation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fémur , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Rotación , Fémur/cirugía , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular , Dolor Postoperatorio/prevención & control , Dolor Postoperatorio/etiología , Resultado del Tratamiento
3.
BMJ Open ; 14(5): e077942, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38719321

RESUMEN

INTRODUCTION: Even when total knee arthroplasty (TKA) is an extended treatment, most patients experience a suboptimal evolution after TKA. The objectives of this study are the following: (1) to determine the effectiveness of two different prosthesis stabilisation systems on the functionality in activities of daily life, and (2) to determine prognostic biomarkers of knee prosthesis function based on radiological information, quantification of cytokines, intra-articular markers and biomechanical functional evaluation to predict successful evolution. METHODS AND ANALYSIS: The PROKnee trial was designed as a randomised controlled patient-blinded trial with two parallel groups that are currently ongoing. The initial recruitment will be 99 patients scheduled for their first TKA, without previous prosthesis interventions in lower limbs, who will be randomly divided into two groups that differed in the stabilisation methodology incorporated in the knee prosthesis: the MEDIAL-pivot group and the CENTRAL-pivot group. The maximum walking speed will be reported as the primary outcome, and the secondary results will be patient-reported questionnaires related to physical status, cognitive and mental state, radiological test, laboratory analysis and biomechanical instrumented functional performance, such as the 6-minute walking test, timed up-and-go test, gait, sit-to-stand, step-over, and ability to step up and down stairs. All the results will be measured 1 week before TKA and at 1.5, 3, 6 and 12 months after surgery. ETHICS AND DISSEMINATION: All procedures were approved by the Ethical Committee for Research with Medicines of the University Clinical Hospital of Valencia on 8 October 2020 (order no. 2020/181). Participants are required to provide informed consent for the study and for the surgical procedure. All the data collected will be treated confidentially since they will be blinded and encrypted. The results from the trial will be published in international peer-reviewed scientific journals, regardless of whether these results are negative or inconclusive. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Registry (NCT04850300).


Asunto(s)
Actividades Cotidianas , Artroplastia de Reemplazo de Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Prótesis de la Rodilla , Recuperación de la Función , Femenino , Masculino , Estudios de Seguimiento , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología
4.
PLoS One ; 19(5): e0302885, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739584

RESUMEN

BACKGROUND: The Vega System® PS (Aesculap AG, Tuttlingen, Germany) is an advanced, third generation fixed implant that aims to mimic natural knee kinematics by optimizing pivotal motion while reducing surface stress. This study evaluated mid-term survival and clinical outcomes, including range of motion (ROM) of the modern posterior stabilized implant in order to analyse whether this biomechanically successful implant reaches good results in situ. METHODS: The first 100 patients to receive the Vega PS System for total knee arthroplasty were invited to take part in this single centre, single surgeon study. Of these, 84 patients were clinically assessed 5-6 years postoperatively. Data which was obtained during this follow-up examination included revision data, range of motion and clinical scores. RESULTS: The 5-year survival rate for exchange of any component was 97.6%, whereby two patients required replacement of the polyethylene gliding surface. Secondary patella resurfacing was performed in 7 patients. Significantly improved results in comparison to the preoperative state could be obtained at the follow-up: KOOS improved from 39.4 to 78.8, SF-12 PCS improved from 32.1 to 42 SF-12 MCS improved from 46 to 53.8 and patella pain improved from 2.7 to 0.3. The mean ROM of the 84 patients after 5 years was 133.1° and mean total KSS was 189.9. DISCUSSION & CONCLUSIONS: This study demonstrates a high survival rate of the Vega PS System® and significant improvements in clinical outcomes 5 years after implantation. The obtained mean ROM indicates that this implant provides good flexibility of the knee joint, allowing a high number of activities. However, due to the rate of secondary patella implantation, routine resurfacing of the patella for all PS TKA cases is highly recommended. CLINICAL TRIALS REGISTRATION: The study was registered at clinicaltrials.gov (NCT02802085).


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Rango del Movimiento Articular , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Masculino , Anciano , Estudios de Seguimiento , Persona de Mediana Edad , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Anciano de 80 o más Años , Actividades Cotidianas , Fenómenos Biomecánicos , Resultado del Tratamiento , Diseño de Prótesis
5.
J Coll Physicians Surg Pak ; 34(5): 610-613, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38720225

RESUMEN

OBJECTIVE: To determine whether the presence of preoperative subchondral bone marrow oedema (SBME) is associated with inferior outcomes after lateral unicompartmental knee arthroplasty (LUKA). STUDY DESIGN: Descriptive study. Place and Duration of the Study: Department of Orthopaedic Surgery, Chongqing Orthopaedic Hospital of Traditional Chinese Medicine, Chongqing, China, from January 2019 to June 2022. METHODOLOGY: Data on patients treated with LUKA were obtained from the Medical Registry Database. Two groups were made based on the presence and absence of SBME on preoperative magnetic resonance imaging (MRI). The visual analogue scale (VAS), American Knee Society Scores (AKSS), and rate of patient satisfaction were compared between the two groups. RESULTS: A total of 20 patients treated with LUKA were reviewed. The SBME was present in 9 cases and absent in 11 cases. Patients with SBME had inferior scores at preoperative evaluation and at 1, 3, and 6 months postoperatively. However, there was no significant difference between the groups at the 12-month follow-up. Eight (88.9%) patients with SBME were satisfied with the LUKA surgery versus 9 (81.8%) patients without SBME, showing no significant differences between groups. CONCLUSION: Presence of preoperative SBME is associated with inferior functional outcomes after LUKA within six months of follow-up. KEY WORDS: Bone marrow, Oedema, Knee, Arthroplasty, Outcome, Patient satisfaction.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Enfermedades de la Médula Ósea , Edema , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Masculino , Femenino , Persona de Mediana Edad , Edema/etiología , Anciano , Enfermedades de la Médula Ósea/cirugía , Resultado del Tratamiento , Imagen por Resonancia Magnética , Satisfacción del Paciente , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Periodo Preoperatorio , Médula Ósea/patología , China/epidemiología
6.
Jt Dis Relat Surg ; 35(2): 330-339, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727112

RESUMEN

OBJECTIVES: The study aims to investigate the relationship between the vastus medialis obliquus (VMO) muscle distal insertion features and patellar chondral lesion presence. PATIENTS AND METHODS: This cross-sectional study included a total of 100 patients (18 males, 82 females, mean age 67.2±7.1 years; range, 50 to 86 years) who underwent total knee arthroplasty (TKA). Radiological assessments, including merchant view and standing orthoroentgenograms, were conducted. The current osteoarthritis stage, varus angle, quadriceps angle (Q angle), patella-patellar tendon angle (P-PT angle), congruence angle, and sulcus angle were calculated. The VMO tendon length, muscle fiber angle, tendon insertion width measurements, and patellar chondral lesion localization data were obtained intraoperatively. Grouping was done according to the distal insertion width of the VMO tendon to the medial edge of the patella. The medial rim of the patella was divided into three equal-sized sectors. The first group (Group 1, n=31) consisted of patients who had an insertion from the quadriceps tendon into the upper one-third of the patella. The second group (Group 1, n=48) consisted of patients with a distal insertion expanding into the middle one-third of the patella. The third group (Group 3, n=21) consisted of patients who had a distal insertion extending into the distal third region of the medial patella margin. The patella joint surface was divided into sectors, and the presence and location of cartilage lesions were noted in detail. RESULTS: The mean tendon insertion width rate was 45.99±16.886% (range, 16.7 to 83.3%). The mean muscle fiber insertion angle was 51.85±11.67º (range, 20º to 80º). The mean tendon length was 12.45±3.289 (range, 4 to 20) mm. There was no significant difference between the mean age, weight, height, body mass index, BMI, fiber angle, tendon length, varus angle, Q angle, sulcus angle, and congruence angle data among the groups. In terms of the P-PT angle, Groups 1 and 2 had a significant relationship (p=0.008). No relationship was found between the mean fiber insertion angle, mean tendon length, or the presence of chondral lesions. There was a statistically significant difference among the groups regarding the presence of chondral lesions. The highest percentage of chondral lesion frequency was observed in Group 3 (95.24%), followed by Group 1 (90.3%) and Group 2 (89.6%), respectively. Compared to the other two groups, Group 3 had a higher average ratio of lesion areas per patient. CONCLUSION: Our study results demonstrate that the formation and localization of the patellar chondral lesions are affected by the insertion width type of the VMO muscle into the patella. Group 2-type insertion is associated with a lower lesion frequency rate than Groups 1 and 3.


Asunto(s)
Rótula , Músculo Cuádriceps , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Músculo Cuádriceps/patología , Músculo Cuádriceps/diagnóstico por imagen , Estudios Transversales , Anciano de 80 o más Años , Rótula/patología , Rótula/diagnóstico por imagen , Rótula/anatomía & histología , Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/patología , Osteoartritis de la Rodilla/diagnóstico por imagen , Cartílago Articular/patología , Cartílago Articular/diagnóstico por imagen , Radiografía , Articulación de la Rodilla/patología , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen
7.
Jt Dis Relat Surg ; 35(2): 305-314, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727109

RESUMEN

OBJECTIVES: This study aimed to explore the use of Gerdy's tubercle (GT) as an innovative and dependable anatomical landmark for the proximal tibial cut in total knee arthroplasty (TKA) in cases with extensive knee degeneration. MATERIALS AND METHODS: One hundred dry tibia bones and 10 formalin-fixed cadaveric knee specimens of both sexes were examined. A Zimmer NexGen tibial cutting guide and a Mitutoyo digital caliper were utilized to align the guide with the tibia's mechanical axis. The procedure was replicated on cadaver knees using a standardized medial parapatellar arthrotomy approach. Measurements included the distance from GT superior border to the resection line and the length of the tibia. A radiological study involving magnetic resonance imaging examinations of 48 patients, which were evaluated focusing on the upper border of GT and the least degenerated segment of the posterolateral part of the lateral tibial condyle, was conducted. RESULTS: Anatomical measurements of GT and proximal tibial areas in 110 specimens showed slight but consistent variations with cadaver measurements. Magnetic resonance imaging analysis of 48 patients revealed notable sex differences in the distance between the superior border of GT and the tibia's posterolateral surface. There was also a significant negative correlation between the distance from GT to the posterolateral corner and cartilage thickness. CONCLUSION: Proper alignment in TKA is crucial for success, but identifying an extra-articular landmark for horizontal tibial resection remains challenging, particularly in severely arthritic knees. This study introduces GT as a novel anatomical landmark for TKA, offering a more reliable reference for achieving desired joint levels in knees with significant degenerative changes.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Cadáver , Imagen por Resonancia Magnética , Tibia , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Masculino , Femenino , Tibia/cirugía , Tibia/anatomía & histología , Tibia/diagnóstico por imagen , Anciano , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/anatomía & histología , Articulación de la Rodilla/patología , Puntos Anatómicos de Referencia , Anciano de 80 o más Años
8.
Jt Dis Relat Surg ; 35(2): 361-367, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38727116

RESUMEN

OBJECTIVES: This study aims to compare the radiological, biomechanical, and histopathological results of microfracture treatment and osteochondral damage repair treatment with a new scaffold product produced by the three-dimensional (3D) bioprinting method containing gelatin-hyaluronic acid-alginate in rabbits with osteochondral damage. MATERIALS AND METHODS: A new 3D bioprinted scaffold consisting of gelatin, hyaluronic acid, and alginate designed by us was implanted into the osteochondral defect created in the femoral trochlea of 10 rabbits. By randomization, it was determined which side of 10 rabbits would be repaired with a 3D bioprinted scaffold, and microfracture treatment was applied to the other knees of the rabbits. After six months of follow-up, the rabbits were sacrificed. The results of both treatment groups were compared radiologically, biomechanically, and histopathologically. RESULTS: None of the rabbits experienced any complications. The magnetic resonance imaging evaluation showed that all osteochondral defect areas were integrated with healthy cartilage in both groups. There was no significant difference between the groups in the biomechanical load test (p=0.579). No statistically significant difference was detected in the histological examination using the modified Wakitani scores (p=0.731). CONCLUSION: Our study results showed that 3D bioprinted scaffolds exhibited comparable radiological, biomechanical, and histological properties to the conventional microfracture technique for osteochondral defect treatment.


Asunto(s)
Alginatos , Bioimpresión , Cartílago Articular , Gelatina , Ácido Hialurónico , Articulación de la Rodilla , Impresión Tridimensional , Andamios del Tejido , Animales , Conejos , Alginatos/química , Gelatina/química , Ácido Hialurónico/química , Ácido Hialurónico/uso terapéutico , Andamios del Tejido/química , Cartílago Articular/patología , Cartílago Articular/lesiones , Cartílago Articular/cirugía , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/patología , Bioimpresión/métodos , Modelos Animales de Enfermedad , Fenómenos Biomecánicos , Imagen por Resonancia Magnética , Artroplastia Subcondral/métodos
9.
Jt Dis Relat Surg ; 35(2): 422-432, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38727124

RESUMEN

Distal femoral varus osteotomy (DFVO) is a widely recognized surgical procedure used to address valgus malalignment in patients with knee joint disorders. However, it still remains unclear whether anterior cruciate ligament (ACL) reconstruction can be performed in a single procedure along with DFVO. Herein, we present a 73-year-old female patient who developed lateral osteoarthritis of the knee with valgus alignment due to chronic ACL deficiency following a twisting injury during skiing. She was physiologically very active, and strongly demanded to return to sports. We performed a combined procedure involving a medial closing wedge DFVO using an anatomical locking plate, along with double-bundle ACL reconstruction. The postoperative radiograph confirmed successful correction of knee alignment, specifically achieving varus alignment with precise conformance of the anatomical plate to the medial contour of the distal femur following the osteotomy. The patient resumed her previous sports activities without experiencing knee pain. The operated knee demonstrated restored anterior stability, as indicated by negative Lachman test results, and regained full range of motion. Both the Knee Injury and Osteoarthritis Outcome Score and the 2011 Knee Society score demonstrated continuous postoperative improvements over the three-year follow-up period, indicating positive functional outcomes and joint preservation. To the best of our knowledge, this is the first case of medial closing wedge DFVO with anatomic double-bundle ACL reconstruction in the symptomatic femoral valgus deformity with chronic ACL deficiency in the literature.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Fémur , Osteoartritis de la Rodilla , Osteotomía , Humanos , Femenino , Osteotomía/métodos , Anciano , Fémur/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/anomalías , Articulación de la Rodilla/diagnóstico por imagen , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/complicaciones , Resultado del Tratamiento , Rango del Movimiento Articular
10.
Jt Dis Relat Surg ; 35(2): 396-403, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38727120

RESUMEN

OBJECTIVES: This study aimed to compare the functional outcomes of patients undergoing fixed-bearing medial unicompartmental knee arthroplasty (UKA) classified as either varus or neutral based on their postoperative femorotibial angle (FTA), with the goal of evaluating the impact of FTA on functional results. PATIENTS AND METHODS: A total of 38 knees of 35 patients (27 females, 8 males; mean age: 63.6±7.1 years; range, 52 to 75 years) were included in this retrospective study. The data was collected between December 15, 2020, and January 15, 2021. Patients were categorized into two groups based on their postoperative FTA. The neutral group consisted of patients with an FTA range of 5.1° to 7.4°, while the varus group included patients with an FTA range of 0.1° to 4.8°. Knee Outcome Osteoarthritis Score (KOOS), Visual Analog Scale (VAS) scores, sit to stand test results, and six minute walk test data were analyzed. RESULTS: The mean follow-up was 42.0±19.3 months. The postoperative VAS score for the varus group was 0.95±0.99, whereas the neutral group had a VAS score of 2.19±1.83 (p=0.021). The mean KOOS for the varus group was 88.01±7.88, whereas the neutral group had a mean KOOS score of 78.46±13.69 (p=0.006). CONCLUSION: In patients undergoing UKA, mild varus alignment could yield superior early and midterm functional outcomes compared to a neutral femorotibial angle.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Fémur , Osteoartritis de la Rodilla , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/fisiopatología , Fémur/cirugía , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular , Resultado del Tratamiento , Tibia/cirugía , Prótesis de la Rodilla , Recuperación de la Función
11.
Zhonghua Yi Xue Za Zhi ; 104(17): 1474-1480, 2024 May 07.
Artículo en Chino | MEDLINE | ID: mdl-38706053

RESUMEN

Objective: To explore the efficacy of arthroscopic release in treating postoperative knee adhesion and investigate the influence of release timing on the treatment outcomes. Methods: A total of 50 patients who accepted arthroscopic release in Peking University Third Hospital from February 2017 to December 2021 were included in the retrospective cohort. The study cohort comprised 28 men and 22 women, with a mean age of (30.8±11.9) years. All the primary surgeries were manipulated under arthroscopes. A comparison was made between pre-and postoperative range of motion (ROM), visual analog scale (VAS), International Knee Documentation Committee (IKDC) scores, and Tegner activity scale scores for the patients. According to the interval between the appearance of adhesion and arthroscopic release, the patients were divided into four groups:<3 months group (n=12), 3-6 months group (n=16),>6-12 months group (n=14), and>12 months group (n=8). Inter-group comparisons on postoperative ROM, IKDC scores, and Tegner activity scale scores and improvement values of each outcome were conducted. Results: All the patients were followed up for (36.4±19.7) months. Patients gained significant improvement in flexion, extension, IKDC scores, and Tegner scores (125.0°±20.0° vs 75.7°±27.5°, 2.3°±4.8° vs 7.4°±7.3°, 69.8±17.7 vs 51.4±12.8, 4.1±2.1 vs 2.2±1.1) (all P<0.05), while the VAS scores did not show significant improvement. There were no significant differences among different groups in postoperative extension, IKDC scores or Tegner scores, nor in their improvements. However, patients in the ≤6 months group could gain better postoperative flexion and improvement in flexion than those in the >6 months group (129.9°±20.0° vs 118.8°±17.4°, 58.6°±32.8° vs 37.3°±23.1°) (P<0.05). Conclusions: Arthroscopic release presents a great effect in treating knee adhesion after arthroscopic operation. Once the symptoms of adhesion appear and physical rehabilitation fails to improve the ROM, one should accept early surgical intervention (less than 6 months) for a better outcome.


Asunto(s)
Artroscopía , Articulación de la Rodilla , Rango del Movimiento Articular , Humanos , Femenino , Masculino , Adulto , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Adherencias Tisulares , Resultado del Tratamiento , Complicaciones Posoperatorias , Factores de Tiempo
12.
Zhonghua Yi Xue Za Zhi ; 104(17): 1481-1485, 2024 May 07.
Artículo en Chino | MEDLINE | ID: mdl-38706054

RESUMEN

Objective: To evaluate the efficacy of medial open wedge high tibial osteotomy (MOWHTO) combined with anterior cruciate ligament (ACL) reconstruction in the treatment of varus knee osteoarthritis (OA) with ACL injury. Methods: A follow-up study. The study retrospectively analyzed the patients underwent MOWHTO combined with ACL reconstruction for treatment of varus knee OA with ACL injury in Tianjin Hospital between April 2018 and September 2022. The preoperative and postoperative posterior slope angle (PSA), hip-knee-ankle angle (HKA), visual analog scale (VAS) pain scores, Lysholm score, International Knee Documentation Committee (IKDC) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Tegner score were compared. The follow-up indicators were recorded at 6 weeks, 3 months and 1 year after operation, and the complications were recorded. Results: The study included 32 patients (23 males, 9 females) with a mean age of (50.7±8.4) years. The mean follow-up time was (21.2±4.8) months. PSA increased from 9.2°±1.8° preoperatively to 11.1°±2.4° postoperatively, and HKA increased from 168.7°±2.2° to 181.5°±2.2° (both P<0.01). The indicators such as VAS score (6.8±1.1 vs 1.8±0.4), Lysholm score (52.6±7.1 vs 82.0±6.4), IKDC score (64.7±6.2 vs 80.3±10.0), WOMAC score (51.8±6.3 vs 81.8±6.5), and Tegner score (1.9±0.6 vs 5.0±1.0) were all improved after the operation (all P<0.01). Complications occurred in 5 patients (15.6%), including hematomas, sensory abnormalities, intermuscular vein thrombosis and correction angle loss. Conclusion: MOWHTO combined with ACL reconstruction is a safe and effective approach for the treatment of varus knee OA with ACL injury.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Osteoartritis de la Rodilla , Osteotomía , Tibia , Humanos , Masculino , Femenino , Osteotomía/métodos , Persona de Mediana Edad , Estudios Retrospectivos , Reconstrucción del Ligamento Cruzado Anterior/métodos , Osteoartritis de la Rodilla/cirugía , Tibia/cirugía , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/complicaciones , Resultado del Tratamiento , Articulación de la Rodilla/cirugía
13.
Zhonghua Yi Xue Za Zhi ; 104(17): 1486-1492, 2024 May 07.
Artículo en Chino | MEDLINE | ID: mdl-38706055

RESUMEN

Objective: To investigate the clinical effect of over-the-top (OTT) reconstruction of the anterior cruciate ligament (ACL) combined with the modified Lemaire technique in one-stage ACL revision. Methods: It's a retrospective study. The clinical data of 37 patients who underwent one-stage revision of ACL using OTT combined with modified Lemaire technique from April 2020 to May 2023 in the Department of Sports Medicine of Xinhua Hospital Affiliated to Dalian University were retrospectively analyzed. There were 28 males and 9 females with a mean age of (32.7±5.7) years. The postoperative knee function and surgical revision effect were evaluated by subjective and objective evaluation indexes of the knee joint before and 3 months and 24 months after surgery. The subjective evaluation indexes included the International Knee Documentation Committee (IKDC) score, Lysholm score, and Tegner score; and the objective evaluation indexes included the anterior-posterior static displacement distance of the tibia, tibia-femur relative rotation angle, the Lachman test, the axial shift test, and the ratio of the loss of muscle strength of the lower limb. Results: At the final follow-up, all patients returned to pre-injury motor level, with significant improvements in IKDC scores (45.3±6.8 preoperatively, 67.5±4.7 and 93.2±2.3 at 3 months and 2 years after the operation, respectively), Lysholm scores (57.2±2.6 preoperatively, 72.6±2.9 and 89.7±3.7 at 3 months and 2 years after the operation, respectively), and Tegner scores (3.1±0.7 preoperatively, 4.9±0.6 and 5.8±1.3 at 3 months and 2 years after the operation, respectively) (all P<0.001). The anterior-posterior static displacement distance of the tibia reduced significantly [from (5.2±0.5) mm before the operation to (1.4±0.5) mm at 2 years postoperatively) (P<0.001)]; and the relative rotation angle of the tibia-femur restored to the normal physiological range, it was reduced from 6.2°±1.2° before the operation to 1.7°±0.3° 2 years after (P<0.001). The Lachman test and axial shift test at 2 years postoperatively were all negative. The muscle strength loss ratio of the affected lower limb was significantly better than that before the operation (P<0.001). Conclusion: The use of OTT reconstruction combined with modified Lemaire technique for revision of ACL in patients with ACL reconstruction failure can circumvent the tunnel problem for one-stage revision and better restore the stability and function of the knee joint, with ideal clinical results.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior , Humanos , Reconstrucción del Ligamento Cruzado Anterior/métodos , Masculino , Femenino , Adulto , Estudios Retrospectivos , Resultado del Tratamiento , Lesiones del Ligamento Cruzado Anterior/cirugía , Ligamento Cruzado Anterior/cirugía , Articulación de la Rodilla/cirugía
14.
PLoS One ; 19(5): e0302839, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38696506

RESUMEN

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Asunto(s)
Hilos Ortopédicos , Fijación Interna de Fracturas , Fracturas Conminutas , Rótula , Humanos , Masculino , Femenino , Adulto , Rótula/cirugía , Rótula/lesiones , Fracturas Conminutas/cirugía , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Estudios Retrospectivos , Persona de Mediana Edad , Rango del Movimiento Articular , Resultado del Tratamiento , Fracturas Óseas/cirugía , Curación de Fractura , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Adulto Joven , Tornillos Óseos , Anclas para Sutura
15.
Anesthesiol Clin ; 42(2): 247-261, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38705674

RESUMEN

Anesthesia for patients undergoing knee procedures encompasses a large patient population with significant variation in patient age, comorbidities, and type of surgery. In addition, these procedures are performed in vastly different surgical environments, including large academic hospitals, private hospitals, and out-patient surgical centers. These variabilities require a thoughtful and individualized anesthetic approach tailored toward the medical and surgical needs of each patient. This article discusses anesthetic approaches to patients with acute, subacute, and chronic knee-related pathology requiring surgery. We will also review pertinent knee anatomy and innervation and discuss regional nerve blocks and their applications to knee-related surgical procedures.


Asunto(s)
Anestesia , Humanos , Anestesia/métodos , Articulación de la Rodilla/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Bloqueo Nervioso/métodos , Rodilla/cirugía
16.
Bull Hosp Jt Dis (2013) ; 82(2): 139-145, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38739662

RESUMEN

PURPOSE: This study aimed to evaluate implant survivor-ship, complications, and re-operation rates following robotic arm-assisted unicompartmental knee arthroplasty (UKA) at mid-term follow-up. METHODS: Patient satisfaction, clinical outcome, and knee alignment restoration were evaluated. All patients undergo-ing robotic arm-assisted medial UKA during a 2-year period were prospectively enrolled. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, varus-valgus deformity, and knee range of motion were studied pre- and postoperatively. Revisions and surgery-related complications were recorded. RESULTS: Eighty-five patients were included in the study (mean age: 71.2 years). The mean follow-up was 74.7 months. One conversion to total knee arthroplasty was performed due to periprosthetic fracture 4.5 years after initial surgery result-ing in a survivorship rate of 98.8%. Overall satisfaction was excellent; 97.7% of patients were satisfied or very satisfied, while none was dissatisfied or very dissatisfied. WOMAC score in total, as well as in each component, exhibited sig-nificant improvement postoperatively. Additionally, knee alignment in the coronal plane as well as flexion contracture were significantly improved following the procedure. CONCLUSIONS: The outcomes of the present cohort revealed that precise prosthesis implantation through the robotic arm-assisted system in UKA provided excellent overall satisfac-tion rates and clinical outcomes at mid-term follow-up.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Prótesis de la Rodilla , Satisfacción del Paciente , Rango del Movimiento Articular , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/instrumentación , Anciano , Femenino , Masculino , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Resultado del Tratamiento , Persona de Mediana Edad , Satisfacción del Paciente/estadística & datos numéricos , Estudios de Seguimiento , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/fisiopatología , Reoperación/estadística & datos numéricos , Anciano de 80 o más Años , Recuperación de la Función , Estudios Prospectivos , Complicaciones Posoperatorias/etiología , Factores de Tiempo
17.
Bull Hosp Jt Dis (2013) ; 82(2): 118-123, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38739659

RESUMEN

OBJECTIVE: The purpose of this study was to compare the short-term clinical outcomes of matrix-induced autologous chondrocyte implantation (MACI) to those seen following traditional autologous chondrocyte implantation (ACI) in the management of symptomatic cartilage lesions of the knee. METHODS: This was a retrospective cohort study of patients who underwent either ACI or MACI from January 2011 to March 2018. Patients with a minimum postoperative follow-up of 18 months were contacted. Demographic information, intraoperative findings, and patient-reported functional outcomes scores were collected. Comparisons were made between the two cell-based cartilage repair techniques. RESULTS: Fifty-six patients were included in the study (39 ACI, 17 MACI). Visual analog scale (VAS) for pain scores improved significantly in both groups, with MACI patients demonstrating significantly lower postoperative pain scores compared to those treated with ACI. In the ACI group, there was a decrease in the Tegner Activity score compared to the preoperative baseline, while no significant difference was seen between pre- and postoperative activity levels in the MACI group. Patients were generally satisfied with the outcome of their procedures, and there was no significant difference in satisfaction between groups. No patients re-quired additional surgery during the follow-up period. CONCLUSION: Both ACI and MACI demonstrated good short-term postoperative clinical results with improved pain and activity levels compared to the preoperative baseline. Patients treated with the MACI technique demonstrated greater reductions in pain scores compared to ACI, and while ACI resulted in a decrease in levels of postoperative activity, activity levels for MACI remained stable.


Asunto(s)
Condrocitos , Articulación de la Rodilla , Trasplante Autólogo , Humanos , Condrocitos/trasplante , Estudios Retrospectivos , Femenino , Masculino , Adulto , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Persona de Mediana Edad , Cartílago Articular/cirugía , Dimensión del Dolor , Satisfacción del Paciente , Adulto Joven
18.
BMC Musculoskelet Disord ; 25(1): 370, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38730370

RESUMEN

BACKGROUND: In this study, we present the unique case of a patient with knee osteoarthritis (OA) of the medial compartment and posterior cruciate ligament (PCL) deficiency who underwent simultaneous medial unicompartmental knee arthroplasty (UKA) and PCL reconstruction. CASE PRESENTATION: A 49-year-old male patient presented with a 1-year history of pain and instability in the left knee. The patient had previously experienced a trauma-related injury to the PCL of the left knee that was left untreated. Imaging and physical examination confirmed the presence of left medial knee OA along with PCL rupture. To address these issues, the patient underwent UKA combined with PCL reconstruction. The patient's Lysholm score was 47 before surgery and 81 three months after surgery, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score was 29 before surgery and 18 three months after surgery, and the International Knee Documentation Committee (IKDC) subjective score was 56.3 before surgery and 74.7 three months after surgery. Six months after surgery, the patient's gait returned to normal, and he was able to jog. CONCLUSION: This case report presents the first instance of UKA combined with PCL reconstruction and introduces a novel treatment approach for patients suffering from medial knee OA and ligament injury.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Reconstrucción del Ligamento Cruzado Posterior , Ligamento Cruzado Posterior , Humanos , Masculino , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/métodos , Osteoartritis de la Rodilla/cirugía , Reconstrucción del Ligamento Cruzado Posterior/métodos , Ligamento Cruzado Posterior/cirugía , Ligamento Cruzado Posterior/lesiones , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen
19.
Int Orthop ; 48(6): 1427-1438, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38558191

RESUMEN

PURPOSE: To present the technique of correction of multiplanar deformities around the knee in children and adolescents using the monolateral external fixator. Also, to evaluate the results of the technique regarding radiological correction, time to union, and possible complications. METHODS: A total of 29 patients (47 limbs) were prospectively included in the study (14 males and 15 females). Their median age was 13 years (range, 7-17). All patients had at least a 2-plane deformity around the knee which was corrected using a monolateral external fixator. The primary outcome measure was deformity correction (correction of mechanical axis deviation (MAD) in both the coronal and sagittal planes with correction of rotational deformities). The secondary outcome measures included bony union, radiographic, and functional results (assessed by using the Association for the Study and Application of the Method of Ilizarov (ASAMI) score). RESULTS: The median pre-operative MAD improved from 6.3 to 0.4 cm post-operatively. According to the ASAMI scoring system, the radiographic scoring was excellent in all cases (100%), and the functional scoring was excellent in 22 cases (89.7%) and good in three cases (10.3%). CONCLUSION: The simple monolateral fixator can be an effective tool for multiplanar correction of complex deformities around the knee without limb length discrepancy.


Asunto(s)
Fijadores Externos , Articulación de la Rodilla , Humanos , Adolescente , Femenino , Niño , Masculino , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/anomalías , Estudios Prospectivos , Radiografía/métodos , Resultado del Tratamiento , Técnica de Ilizarov/instrumentación
20.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 498-504, 2024 Apr 15.
Artículo en Chino | MEDLINE | ID: mdl-38632073

RESUMEN

Objective: To review the concept and methods of femoral bone tunnel positioning in anterior cruciate ligament (ACL) reconstruction, in order to provide a reference for clinical treatment. Methods: The relevant literature on the concept and methods of femoral bone tunnel positioning in ACL reconstruction in domestic and international research was extensively reviewed. Results: The position of the femoral bone tunnel is a key factor in determining the prognosis of ACL reconstruction. The concept of femoral bone tunnel positioning in ACL reconstruction has experienced isometric reconstruction, anatomical reconstruction, Ribbon-like theory, I.D.E.A.L. theory, and nearly isometric reconstruction theory. The femoral bone tunnel positioning technique is also changing with the in-depth study of the anatomy and biomechanics of the ACL, and each bone tunnel positioning technique has its own advantages and disadvantages. Over-The-Top technique is now mainly used for ACL revision; the clock-face positioning method is basically no longer applicable due to the large error, poor stability, and low retrievability; the bone landmarks positioning method (the lateral condyle of the femur's Resident's ridge and bifurcation ridge, and the the apex of the deep cartilage), which is now mostly used clinically due to the more constant anatomical landmarks. The quadrant method under X-ray fluoroscopy is more cumbersome to implement intraoperatively, so it is mainly used for academic research; computer navigation-assisted positioning has gradually become popular in recent years, which is highly accurate, avoids the influence of human factors on the positioning of the bone tunnel, and has a very good prospect of application; three-dimensional printing-assisted positioning technology, which is accurate in positioning, with a high degree of reproducibility and a short learning curve. Conclusion: The concept of femoral bone tunnel positioning for ACL reconstruction has undergone several evolutions, reflecting the deepening of the understanding of ACL and the improvement of the clinical results of reconstruction. The precision, personalization, and intelligence of positioning techniques are the focus of current and future development.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Humanos , Tibia/cirugía , Reproducibilidad de los Resultados , Fémur/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Fenómenos Biomecánicos , Lesiones del Ligamento Cruzado Anterior/cirugía , Articulación de la Rodilla/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA